PROGRAMMING ALGORITHM
Factory pre-programmed
Adjustable
Unit
Trigger duration
1 sec after leaving the sensor scope 0…10
0,5 s
Safety switch off
after 55 sec
5 … 120
5 s
Automatic flushing
off
1 h
Duration of automatic flushing
15 sec
1…240
1 s
Cleansing mode
available
-
-
Constant running mode for thermo-disinfection
1…120
1 min
Alterable pre-programmed parameters:
Fixed pre-programmed parameters
Program
Description
Scope
Time unit
Factory programming
Designation
The sensor triggering function can be switched off for as long as it is needed to cleanse the basin or the mixer. Valve can be open for some time->thermo- disinfection. Check which program is currently set.
1. Cleansing
2. Disinfection
3. Diagnosis
We can undertake the following settings here.
4. Parameter
4.1. Hand washing Water flows for as long as the sensor is triggered.
- 2-second after-function after the sensor is no longer triggered - Safety-Stop after 55 seconds constant functioning.
4.1.1. Auto-flushing Off
6, 12, 24, 48, 72 Hours
4.1.2. Duration (auto flushing)
15s
1...240
1s
4.2. Auto-shut down
After triggering of the sensors the water
4.2.1. Delayed comfort (duration of water flow after the triggering)
1, 2, 3, 25, 7,5, 10, 15, 30, 60, 120, 240
15s
Seconds
continues flowing for the pre-programmed duration.
4.2.2. Auto-flushing Off
6, 12, 24, 48, 72 Hours
4.2.3. Duration (auto-flushing)
15s
1...240
1s
4.3. ON/OFF
Sensor functions as First switch - ON Second switch - OFF
4.3.1. Delayed comfort (duration of water flow after the triggering)
3, 25, 7,5, 10, 15, 30, 60, 120, 240
15s
Seconds
(About DELAYED COMFORT there is a pre-programmed maximum flow duration which cannot be exceeded).
4.3.2. Auto-flushing Off
6, 12, 24, 48, 72 Hours
4.3.3. Duration (auto-flushing)
15s
1...240
10s
4.4. Urinal
Water flows after the sensor is no longer triggered – Sensor accepts trigger order 3 seconds after triggering (no triggering by walking by). After a 3-second delay after the triggering there follows pre-flushing, after that (as in 4.4) water flows, after the sensor is no longer triggered.
5 seconds after the sensor is no longer triggered, there follows an activation of the flushing.
4.4.1.Flushing (Duration)
8s
0,25...10
0,25s
4.4.2. Auto-flushing 24h
6, 12, 24,48, 72 Hours
4.4.3. Duration (auto-flushing) 4.5.1.Flushing (Duration)
8s
0...240
1s
4.5. Urinal +
Sensor accepts a triggering order 3 seconds after triggering (no triggering by walking by) and flushes directly for 1,5 – 5 seconds after the sensor is no longer triggered, there follows the activation of the flushing.
8s
0,25...10
0,25s
Pre-Flushing
4.5.2. Auto-flushing 24h
6, 12, 24,48, 72 Hours
4.5.3. Duration (auto-flushing)
8s
0...240
1s