Multiple toilet facilities
Four cubicle combination This layout provides a compliant example of a four-cubicle washroom configuration, demonstrating the balance of standard, ambulant and enlarged cubicles required under Document M and Document T.
Key requirements All washrooms must include at least one ambulant cubicle. For every four cubicles (including the ambulant), there must be one enlarged cubicle. This combination supports a wide range of user needs, ensuring both accessibility and convenience while maintaining compliance with Document M, Document T and BS 8300-2:2018.
1200mm minimum
920mm minimum
910mm minimum
910mm minimum
210mm
210mm
210mm
210mm
Shelf 250
Shelf 250
Shelf 250
Shelf 250
x 150mm
x 150mm
x 150mm
x 150mm
Horizontal nappy change unit (folds up to approx. 100mm)
540mm
Space for disposal bin
Space for disposal bin
Space for disposal bin
Space for disposal bin
600mm
1740mm minimum
Activity Space 600 x 800mm
Activity Space 600 x 800mm
200mm
200mm
1465mm minimum
Ø465mm
Ø465mm
Ø465mm
Ø465mm
Coat hooks @ 1685 & 1050mm above
Coat hooks @ 1685 & 1050mm above
60mm
Activity Space 600 x 800mm
Activity Space 600 x 800mm
Coat hooks @ 1685 & 1050mm above
Coat hooks @ 1685 & 1050mm above
650mm
650mm
500mm
500mm
750mm
750mm